Get logical value for y axis scaling
Arguments
- accdat
data.framefor data quality objectives file for accuracy as returned byreadMWRacc- param
character string for the parameter to evaluate as provided in the
"Parameter"column of"accdat"- yscl
character indicating one of
"auto"(default),"log", or"linear"
Examples
# accuracy path
accpth <- system.file('extdata/ExampleDQOAccuracy.xlsx',
package = 'MassWateR')
# accuracy data
accdat <- readMWRacc(accpth)
#> Running checks on data quality objectives for accuracy...
#> Checking column names... OK
#> Checking all required columns are present... OK
#> Checking column types... OK
#> Checking no "na" in Value Range... OK
#> Checking for text other than <=, ≤, <, >=, ≥, >, ±, %, AQL, BQL, log, or all... OK
#> Checking overlaps in Value Range... OK
#> Checking gaps in Value Range... OK
#> Checking Parameter formats... OK
#> Checking for missing entries for unit (uom)... OK
#> Checking if more than one unit (uom) per Parameter... OK
#> Checking acceptable units (uom) for each entry in Parameter... OK
#> Checking empty columns... OK
#>
#> All checks passed!
# log auto
utilMWRyscale(accdat, param = 'E.coli')
#> [1] TRUE
# linear force
utilMWRyscale(accdat, param = 'E.coli', yscl = 'linear')
#> [1] FALSE
# linear auto
utilMWRyscale(accdat, param = 'DO')
#> [1] FALSE
# log force
utilMWRyscale(accdat, param = 'DO', yscl = 'log')
#> [1] TRUE